{"id":4794,"date":"2015-07-16T09:22:08","date_gmt":"2015-07-16T08:22:08","guid":{"rendered":"http:\/\/blog.prefire.es\/?p=4794"},"modified":"2021-01-15T19:15:10","modified_gmt":"2021-01-15T18:15:10","slug":"parametros-necesarios-para-realizar-un-estudio-luminico-con-luz-natural","status":"publish","type":"post","link":"https:\/\/www.prefire.es\/hub\/2015\/07\/parametros-necesarios-para-realizar-un-estudio-luminico-con-luz-natural\/","title":{"rendered":"Par\u00e1metros necesarios para realizar un estudio lum\u00ednico con luz natural"},"content":{"rendered":"<p><a href=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/dialux.png\" rel=\"nofollow noopener\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4967 size-full\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/dialux.png\" alt=\"dialux prefire\" width=\"997\" height=\"168\" srcset=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/dialux.png 997w, https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/dialux-980x165.png 980w, https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/dialux-480x81.png 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 997px, 100vw\" \/><\/a><\/p>\n<p>Si deseamos hacer un estudio lum\u00ednico sobre un local o edificio\u00a0con <strong>lucernarios para la captaci\u00f3n de luz natural<\/strong>, deberemos disponer y tener en consideraci\u00f3n\u00a0 una serie de datos de ante mano que hemos de recopilar para poder realizar un c\u00e1lculo \u00a0de la iluminancia en<strong> un \u00a0plano de trabajo determinado<\/strong>.<\/p>\n<p><!--more--><\/p>\n<p>A continuaci\u00f3n enumeramos los <strong>pasos a seguir y datos\u00a0\u00a0b\u00e1sicos que se requieren obtener<\/strong> para poder realizar un <strong>estudio lum\u00ednico con lucernarios <\/strong><strong>\u00a0mediante \u00a0el\u00a0<\/strong><strong>software\u00a0DIALUX:<\/strong><\/p>\n<p><strong>1.<\/strong><span style=\"text-decoration: underline;\"><strong>DEFINIR LA ESCENA DE LUZ<\/strong><\/span><\/p>\n<ul>\n<li><strong style=\"color: #000000;\">Determinar la fecha<\/strong> concreta a realizar el estudio\u00a0(verano o invierno y hora de toma de datos de radiaci\u00f3n solar).<\/li>\n<li><strong>La situaci\u00f3n geogr\u00e1fica<\/strong> del local indicando la Longitud y Latitud.<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-4795 aligncenter\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/04\/ubicacion.png\" alt=\"ubicacion prefire\" width=\"374\" height=\"256\" srcset=\"https:\/\/www.prefire.es\/hub\/wp-content\/uploads\/2015\/04\/ubicacion.png 378w, https:\/\/www.prefire.es\/hub\/wp-content\/uploads\/2015\/04\/ubicacion-328x225.png 328w\" sizes=\"(max-width: 374px) 100vw, 374px\" \/><\/p>\n<ul>\n<li><strong>Implantaci\u00f3n del local<\/strong>. Hay que tener en cuenta si hay alg\u00fan elemento o edificio que pudiera hacer sombras.<\/li>\n<li><strong>La orientaci\u00f3n<\/strong> de la planta\u00a0del\u00a0 local respecto al norte.<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-4796\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/04\/orientacion.png\" alt=\"orientacion prefire\" width=\"374\" height=\"212\" srcset=\"https:\/\/www.prefire.es\/hub\/wp-content\/uploads\/2015\/04\/orientacion.png 442w, https:\/\/www.prefire.es\/hub\/wp-content\/uploads\/2015\/04\/orientacion-396x225.png 396w\" sizes=\"(max-width: 374px) 100vw, 374px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong style=\"color: #000000; font-style: normal;\">2. <span style=\"text-decoration: underline;\">DEFINIR EL LOCAL<\/span><span style=\"text-decoration: underline;\">:<\/span><\/strong><\/p>\n<ul>\n<li><strong>Dimensiones \u00a0y geometr\u00eda<\/strong> (ancho, alto y altura).<\/li>\n<li><strong>Tipo de cubierta<\/strong> (plana o inclinada).<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4975 size-large\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/LOCAL1-1024x895.png\" alt=\"LOCAL DIALUX prefire\" width=\"584\" height=\"510\" \/><\/p>\n<ul>\n<li><strong>Materiales y colores<\/strong>\u00a0de los elementos que limitan (suelo, paredes y techo).<\/li>\n<\/ul>\n<p><a href=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/sup-local.png\" rel=\"nofollow noopener\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4991 size-full\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/sup-local.png\" alt=\"sup local\" width=\"318\" height=\"252\" srcset=\"https:\/\/www.prefire.es\/hub\/wp-content\/uploads\/2015\/07\/sup-local.png 318w, https:\/\/www.prefire.es\/hub\/wp-content\/uploads\/2015\/07\/sup-local-284x225.png 284w\" sizes=\"(max-width: 318px) 100vw, 318px\" \/><\/a><\/p>\n<ul>\n<li><strong>M\u00e9todo del plan de mantenimiento<\/strong> del local para conocer el factor de degradaci\u00f3n<\/li>\n<\/ul>\n<p><a href=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/mantenimiento.png\" rel=\"nofollow noopener\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4988\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/mantenimiento.png\" alt=\"mantenimiento\" width=\"432\" height=\"257\" srcset=\"https:\/\/www.prefire.es\/hub\/wp-content\/uploads\/2015\/07\/mantenimiento.png 432w, https:\/\/www.prefire.es\/hub\/wp-content\/uploads\/2015\/07\/mantenimiento-378x225.png 378w\" sizes=\"(max-width: 432px) 100vw, 432px\" \/><\/a><\/p>\n<p><strong>3.\u00a0<span style=\"text-decoration: underline;\">DEFINIR LOS LUCERNARIOS:<\/span><\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4966\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/IMG_0039-300x222.jpg\" alt=\"LUCERNARIO PREFIRE\" width=\"374\" height=\"278\" \/><\/p>\n<ul>\n<li><strong>Definir medidas<\/strong> de la parte transmisora (valores a y b).<\/li>\n<li><strong>Definir n\u00famero y\u00a0ubicaci\u00f3n<\/strong>\u00a0dentro del local (valores c y d).<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4808 size-full\" style=\"color: #000000;\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/04\/lucernarios.png\" alt=\"lucernarios prefire dialux\" width=\"374\" height=\"244\" srcset=\"https:\/\/www.prefire.es\/hub\/wp-content\/uploads\/2015\/04\/lucernarios.png 374w, https:\/\/www.prefire.es\/hub\/wp-content\/uploads\/2015\/04\/lucernarios-345x225.png 345w\" sizes=\"(max-width: 374px) 100vw, 374px\" \/><\/p>\n<ul>\n<li><strong>El tipo de material<\/strong> de que est\u00e1 formado (<strong>met\u00e1lico, pl\u00e1stico,\u2026<\/strong>.)<\/li>\n<li><strong>Grado de reflexi\u00f3n del material<\/strong> (importante tener en cuenta la cara interior del z\u00f3calo del lucernario)<\/li>\n<li><strong>El grado de transmisi\u00f3n<\/strong> del material de la c\u00fapula (vidrio, mate, protecci\u00f3n solar, seguridad amado \u2026)<\/li>\n<li><strong>El factor de contaminaci\u00f3n<\/strong> que afecta al lucernario seg\u00fan la zona en la que se sit\u00fae (industrial, rural o residencial)<\/li>\n<li><strong>El factor de divisi\u00f3n de los travesa\u00f1os<\/strong> que presente el lucernario y que afecta a la cantidad de transmisi\u00f3n interiores debido a los elementos que obstruyen.<\/li>\n<\/ul>\n<p><a href=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/factores.png\" rel=\"nofollow noopener\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4983\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/factores.png\" alt=\"factores\" width=\"289\" height=\"289\" srcset=\"https:\/\/www.prefire.es\/hub\/wp-content\/uploads\/2015\/07\/factores.png 289w, https:\/\/www.prefire.es\/hub\/wp-content\/uploads\/2015\/07\/factores-225x225.png 225w\" sizes=\"(max-width: 289px) 100vw, 289px\" \/><\/a><\/p>\n<ul>\n<li><strong>El grado de reflexi\u00f3n, transparencia, y rugosidad del material de la\u00a0c\u00fapula del lucernario<\/strong><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4986\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/material-lucernario.png\" alt=\"material lucernario\" width=\"317\" height=\"286\" srcset=\"https:\/\/www.prefire.es\/hub\/wp-content\/uploads\/2015\/07\/material-lucernario.png 317w, https:\/\/www.prefire.es\/hub\/wp-content\/uploads\/2015\/07\/material-lucernario-249x225.png 249w\" sizes=\"(max-width: 317px) 100vw, 317px\" \/><\/p>\n<ul>\n<li><strong>Longitud de entrada de luz<\/strong><\/li>\n<li><strong>Anchura del pozo de luz<\/strong><\/li>\n<li><strong>Angulo del z\u00f3calo<\/strong><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4801 size-full\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/04\/Plano-de-trabajo.png\" alt=\"Plano de trabajo prefire dialux\" width=\"701\" height=\"489\" srcset=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/04\/Plano-de-trabajo.png 701w, https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/04\/Plano-de-trabajo-480x335.png 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 701px, 100vw\" \/><\/p>\n<p><strong>4.\u00a0<span style=\"text-decoration: underline;\">DEFINIR EL PLANO DE TRABAJO<\/span><\/strong><\/p>\n<ul>\n<li>\u00a0<strong>Definir la a<\/strong><strong style=\"color: #000000; font-style: normal;\">ltura donde se desea obtener los datos lum\u00ednicos<\/strong><\/li>\n<\/ul>\n<p><a href=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/plano-de-trabajo-2.png\" rel=\"nofollow noopener\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4993\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/plano-de-trabajo-2.png\" alt=\"plano de trabajo 2\" width=\"316\" height=\"250\" srcset=\"https:\/\/www.prefire.es\/hub\/wp-content\/uploads\/2015\/07\/plano-de-trabajo-2.png 316w, https:\/\/www.prefire.es\/hub\/wp-content\/uploads\/2015\/07\/plano-de-trabajo-2-284x225.png 284w\" sizes=\"(max-width: 316px) 100vw, 316px\" \/><\/a><\/p>\n<ul>\n<li><strong>Definici\u00f3n de la separaci\u00f3n de las l\u00edneas \u00a0isoluxes para el valor del c\u00e1lculo<\/strong><\/li>\n<\/ul>\n<p><strong style=\"color: #000000; font-style: normal;\"><a href=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/04\/ISOLUX1.png\" rel=\"nofollow noopener\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4804\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/04\/ISOLUX1.png\" alt=\"ISOLUX prefire dialux\" width=\"701\" height=\"673\" srcset=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/04\/ISOLUX1.png 701w, https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/04\/ISOLUX1-480x461.png 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 701px, 100vw\" \/><\/a><\/strong><\/p>\n<p><strong>5.\u00a0<\/strong><span style=\"text-decoration: underline;\"><strong>REALIZAR EL C\u00c1LCULO<\/strong><\/span><\/p>\n<p>Una vez obtenidos todos estos datos, el programa estar\u00eda en condiciones de poder realizar el c\u00e1lculo.<\/p>\n<p><a href=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/calculo.png\" rel=\"nofollow noopener\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4970\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/calculo-1024x731.png\" alt=\"calculo dialux prefire\" width=\"701\" height=\"501\" \/><\/a><\/p>\n<p>Se podr\u00e1n obtener los niveles de iluminancia media (Emin) m\u00e1xima (Emax) y media (Em) en todos los planos de trabajos definidos,\u00a0tanto sea en horizontal como en vertical.<\/p>\n<p><a href=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/RESULTADOS1.png\" rel=\"nofollow noopener\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4972\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/RESULTADOS1-1024x819.png\" alt=\"resultados dialux prefire\" width=\"701\" height=\"561\" \/><\/a><\/p>\n<p><span style=\"text-decoration: underline;\"><strong>OBTENER VISTAS INTERIORES RAY-TRACE\u00a0<\/strong><\/span><\/p>\n<p>Ser\u00e1 posible obtener todas las \u00a0vistas interiores que se hayan definido del local iluminado seg\u00fan los datos introducidos con anterioridad.<\/p>\n<p><a href=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/RAY-TRACE.png\" rel=\"nofollow noopener\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-large wp-image-4994\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/07\/RAY-TRACE-1024x902.png\" alt=\"RAY TRACE\" width=\"584\" height=\"514\" \/><\/a><\/p>\n<p>Hay que tener en cuenta que la<strong> modificaci\u00f3n o variaci\u00f3n de cualquier dato<\/strong> puede llevar a obtener <strong>resultados muy dispares<\/strong>, por lo que es imprescindible ser conscientes y controlar cada par\u00e1metro que se introduce.<\/p>\n<p>Para ello y poder realizar un c\u00e1lculo de lo m\u00e1s veraz \u00a0seg\u00fan el equipo a instalar ser\u00e1 necesario <strong>solicitar al suministrador de los lucernarios las caracter\u00edsticas<\/strong> antes enumeradas\u00a0para poder\u00a0comprobar que se cumplen\u00a0las necesidades que se requieren en cada proyecto.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Si deseamos hacer un estudio lum\u00ednico sobre un local o edificio\u00a0con lucernarios para la captaci\u00f3n de luz natural, deberemos disponer y tener en consideraci\u00f3n\u00a0 una serie de datos de ante mano que hemos de recopilar para poder realizar un c\u00e1lculo \u00a0de la iluminancia en un \u00a0plano de trabajo determinado.<\/p>\n","protected":false},"author":12,"featured_media":4966,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[9],"tags":[72,352,26,353,108],"soporte":[547],"class_list":["post-4794","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-arquitectura-del-vidrio","tag-claraboyas","tag-dialux","tag-diseno","tag-estudio-luminico","tag-lucernarios","soporte-articulo"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/posts\/4794","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/comments?post=4794"}],"version-history":[{"count":43,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/posts\/4794\/revisions"}],"predecessor-version":[{"id":5220,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/posts\/4794\/revisions\/5220"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/media\/4966"}],"wp:attachment":[{"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/media?parent=4794"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/categories?post=4794"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/tags?post=4794"},{"taxonomy":"soporte","embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/soporte?post=4794"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}