{"id":4597,"date":"2015-03-11T09:41:44","date_gmt":"2015-03-11T08:41:44","guid":{"rendered":"http:\/\/blog.prefire.es\/?p=4597"},"modified":"2021-05-31T14:16:24","modified_gmt":"2021-05-31T13:16:24","slug":"la-transmision-luminica-a-la-hora-de-escoger-el-acristalamiento-de-la-claraboya","status":"publish","type":"post","link":"https:\/\/www.prefire.es\/hub\/2015\/03\/la-transmision-luminica-a-la-hora-de-escoger-el-acristalamiento-de-la-claraboya\/","title":{"rendered":"La transmisi\u00f3n lum\u00ednica a la hora de escoger el acristalamiento de la claraboya"},"content":{"rendered":"<p><a href=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/02\/transmision.jpg\" rel=\"nofollow noopener\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4598 size-large\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/02\/TRANSMISION-1080x662.jpg\" alt=\"Transmisi\u00f3n lum\u00ednica en claraboyas de c\u00fapula CI-System F100\" width=\"584\" height=\"357\" \/><\/a><\/p>\n<p>Cuando decidimos instalar una claraboya o un \u00a0lucernario para iluminar un espacio, debemos prestar especial atenci\u00f3n\u00a0a la elecci\u00f3n del material que va a transmitir la luz al interior del edificio.<\/p>\n<p>Cuando los rayos solares inciden en un vidrio, el factor luminoso se divide entre los factores de <strong>transmisi\u00f3n (TL)<\/strong> siendo la luz visible transmitida, la <strong>reflexi\u00f3n de la luz<\/strong>, la reflejada por el acristalamiento (RL) y <strong>la absorbida<\/strong> (AL) por el material.<\/p>\n<p>La elecci\u00f3n del material no ha de ser aleatoria, pues tanto el n\u00famero de capas como de la transparencia de las mismas determina\u00a0el porcentaje de luz, es\u00a0decir, de rayos visibles, transmitidos por el acristalamiento al interior.<\/p>\n<p style=\"text-align: justify;\">Como ejemplo de este concepto presentamos un estudio lum\u00ednico comparativo en <strong>un\u00a0local destinado a oficinas<\/strong> con medidas de 5&#215;5 m con una altura de 2.80 m, con materiales est\u00e1ndar, donde se instala una <a href=\"http:\/\/arquitecturadelvidrio.com\/claraboya-f100.php\" rel=\"nofollow noopener\" target=\"_blank\">claraboya de c\u00fapula CI System\u00a0F100<\/a> de 1.2 m x 1.2 m con material de acabado <a href=\"https:\/\/blog.prefire.es\/2013\/10\/que-es-el-petg\/\" rel=\"nofollow noopener\" target=\"_blank\">PETG<\/a> (polietileno resistente a golpes), donde cambiaremos el <strong>n\u00famero de capas<\/strong> y <strong>la transparencia<\/strong> de las mismas para comprobar como var\u00edan los valores de Iluminancia en el \u00e1rea de trabajo:<\/p>\n<p><a href=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/02\/3D-DESPACHO.png\" rel=\"nofollow noopener\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-4613 size-full\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/02\/3D-DESPACHO.png\" alt=\"estudio luminico despacho- claraboya F100\" width=\"688\" height=\"689\" srcset=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/02\/3D-DESPACHO.png 688w, https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/02\/3D-DESPACHO-480x481.png 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 688px, 100vw\" \/><\/a><\/p>\n<p>Datos:<\/p>\n<ul>\n<li>Dimensiones local: <strong>5&#215;5 m<\/strong><\/li>\n<li>Altura del local: <strong>2.8 m<\/strong><\/li>\n<li>D\u00eda de estudio: <strong>Cielo cubierto<\/strong><\/li>\n<li>Factor de contaminaci\u00f3n: <strong>Residencial 0.8<\/strong><\/li>\n<li>Iluminancia (E) de <strong>450 lux<\/strong>\u00a0requerida en la zona de trabajo<\/li>\n<li>Altura zona de trabajo: <strong>0.75 m <\/strong><\/li>\n<li>Reflexi\u00f3n suelo <strong>20%<\/strong><\/li>\n<li>Reflexi\u00f3n techo <strong>70%<\/strong><\/li>\n<li>Reflexi\u00f3n paredes <strong>50%<\/strong><\/li>\n<li>Tipo de cerramiento c\u00fapula: <strong>PETG<\/strong><\/li>\n<\/ul>\n<p>Obtenemos los siguientes datos\u00a0basados en\u00a0la simulaci\u00f3n lum\u00ednica\u00a0realizados con\u00a0el <strong>programa Dialux<\/strong>:<\/p>\n<p><a href=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/02\/RESULTADOS.png\" rel=\"nofollow noopener\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-4604\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/02\/RESULTADOS.png\" alt=\"Resultados iluminancias- transmisi\u00f3n lum\u00ednica\" width=\"722\" height=\"251\" \/><\/a><\/p>\n<p>En esta tabla podemos observar de los diferentes tipos de modelos de acristalamiento <strong>PETG<\/strong>, formados por <strong>2 \u00f3 3 capas<\/strong> siendo estas <strong>translucidas o transparentes<\/strong> los resultados de iluminancia media (Em) obtenidos en la zona de trabajo h=0.75 m, <strong>siendo las opciones B, C y F<\/strong> las que m\u00e1s se aproximan a la iluminancia requerida de 450 luxes sobre la mesa de trabajo.<\/p>\n<p>Estos datos se pueden apreciar en las\u00a0 <strong>representaciones de las iluminancias a\u00a0colores<\/strong>\u00a0que presentamos a continuaci\u00f3n,\u00a0siendo los colores m\u00e1s c\u00e1lidos donde hay mayor incidencia lum\u00ednica sobre el plano, y los colores fr\u00edos donde hay menor. Como resultado podemos observar que\u00a0 la imagen se har\u00e1 m\u00e1s blanca y c\u00e1lida en cuanto <strong>m\u00e1s transparente sea el material.<\/strong><\/p>\n<p><strong>En el diagrama isolux<\/strong>, se puede observar las curvas de valores iguales en funci\u00f3n de la luz incidente:<\/p>\n<p><a href=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/02\/MODELOS-2-CAPAS-2.png\" rel=\"nofollow noopener\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4616 size-full\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/02\/MODELOS-2-CAPAS-2.png\" alt=\"estudio luminico claraboya f100 2 capas-prefire\" width=\"578\" height=\"836\" srcset=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/02\/MODELOS-2-CAPAS-2.png 578w, https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/02\/MODELOS-2-CAPAS-2-480x694.png 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 578px, 100vw\" \/><\/a><\/p>\n<p><a href=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/02\/MODELOS-2-CAPAS.png\" rel=\"nofollow noopener\" target=\"_blank\">\u00a0<\/a>Diagramas seg\u00fan modelos con 3 capas:<\/p>\n<p><a href=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/02\/MODELOS-3-CAPAS-2.png\" rel=\"nofollow noopener\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4617 size-full\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/02\/MODELOS-3-CAPAS-2.png\" alt=\"estudio luminico claraboya f100-3 capas prefire\" width=\"578\" height=\"789\" srcset=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/02\/MODELOS-3-CAPAS-2.png 578w, https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/02\/MODELOS-3-CAPAS-2-480x655.png 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 578px, 100vw\" \/><\/a><\/p>\n<p>Como <strong>conclusi\u00f3n<\/strong> de los resultados obtenidos podemos destacar:<\/p>\n<p><a href=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/02\/RESULTADOS-comentados2.jpg\" rel=\"nofollow noopener\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4610 size-large\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2015\/02\/RESULTADOS-comentados2-1024x512.jpg\" alt=\"conclusiones estudio luminico prefire\" width=\"584\" height=\"292\" \/><\/a><\/p>\n<ol>\n<li>Caso con <strong>PETG de 2 capas<\/strong><strong style=\"color: #000000; font-style: normal;\"> <strong>( transmisi\u00f3n t\u00e9rmica Ug=2.6 W\/m2K)<\/strong><\/strong>, podemos llegar a tener un 24% de iluminancia media m\u00e1s en el <strong style=\"color: #000000; font-style: normal;\">caso B<\/strong> (translucido\/ transparente) y un 55% en el <strong style=\"color: #000000; font-style: normal;\">caso C<\/strong> (transparente\/transparente) respecto\u00a0al <strong style=\"color: #000000; font-style: normal;\">caso A<\/strong> (translucido\/translucido).<\/li>\n<li>Caso con<strong> PETG de\u00a03 capas<\/strong><strong style=\"color: #000000; font-style: normal;\"> ( transmisi\u00f3n t\u00e9rmica Ug=2.0 W\/m2K)<\/strong>, podemos llegar a tener un 23% de iluminancia media m\u00e1s en el <strong style=\"color: #000000; font-style: normal;\">caso\u00a0E<\/strong>\u00a0 (translucido\/translucido\/ translucido) y un 54% en el <strong style=\"color: #000000; font-style: normal;\">caso\u00a0F<\/strong> (translucido\/transparente\/transparente) respecto el <strong style=\"color: #000000; font-style: normal;\">caso D<\/strong> (translucido\/translucido\/translucido).<\/li>\n<li>Caso <strong>PETG con 2 y 3 capas<\/strong>, podemos sacar la conclusi\u00f3n de que si utilizamos cierre con dos capas podemos llegar a tener valores <strong>entre 38-40% m\u00e1s de luxes<\/strong> en el \u00e1rea de trabajo,\u00a0aunque\u00a0 la soluci\u00f3n de 3 capas presenta un\u00a0<strong>reducci\u00f3n de\u00a0un 23% del coeficiente de transmisi\u00f3n t\u00e9rmica.<\/strong><\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>Cuando decidimos instalar una claraboya o un \u00a0lucernario para iluminar un espacio, debemos prestar especial atenci\u00f3n\u00a0a la elecci\u00f3n del material que va a transmitir la luz al interior del edificio. Cuando los rayos solares inciden en un vidrio, el factor luminoso se divide entre los factores de transmisi\u00f3n (TL) siendo la luz visible transmitida, la [&hellip;]<\/p>\n","protected":false},"author":12,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[9],"tags":[72,352,26,351,353,349,108,350,348],"soporte":[547],"class_list":["post-4597","post","type-post","status-publish","format-standard","hentry","category-arquitectura-del-vidrio","tag-claraboyas","tag-dialux","tag-diseno","tag-eficiencia-luminosa","tag-estudio-luminico","tag-iluminancia","tag-lucernarios","tag-petg","tag-transmision-luminica","soporte-articulo"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/posts\/4597","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/comments?post=4597"}],"version-history":[{"count":32,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/posts\/4597\/revisions"}],"predecessor-version":[{"id":8560,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/posts\/4597\/revisions\/8560"}],"wp:attachment":[{"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/media?parent=4597"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/categories?post=4597"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/tags?post=4597"},{"taxonomy":"soporte","embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/soporte?post=4597"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}