{"id":4025,"date":"2014-09-15T08:02:52","date_gmt":"2014-09-15T07:02:52","guid":{"rendered":"http:\/\/blog.prefire.es\/?p=4025"},"modified":"2021-01-15T19:15:45","modified_gmt":"2021-01-15T18:15:45","slug":"minimos-requerimientos-normativos-proteger-o-cumplir-un-requerimiento","status":"publish","type":"post","link":"https:\/\/www.prefire.es\/hub\/2014\/09\/minimos-requerimientos-normativos-proteger-o-cumplir-un-requerimiento\/","title":{"rendered":"M\u00ednimos requerimientos normativos. \u00bfProteger o cumplir un requerimiento?"},"content":{"rendered":"<p><a href=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2012\/06\/flash_over1.jpg\" rel=\"nofollow noopener\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-1542 size-medium\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2012\/06\/flash_over1-300x213.jpg\" alt=\"flash_over\" width=\"300\" height=\"213\" \/><\/a><\/p>\n<p>Muchos de los proyectos que caen en nuestras manos son susceptibles de este debate, como t\u00e9cnicos y profesionales en Sistemas de Protecci\u00f3n Contra Incendios, siempre debemos priorizar en el dise\u00f1o de nuestros sistemas su principal cometido, \u201cPROTEGER\u201d.<\/p>\n<p>Afortunadamente, y gracias al trabajo de grandes profesionales del sector, la normativa referente a Sistemas Contra Incendios es cada vez m\u00e1s clara, completa y confiere mayor eficacia a las instalaciones basadas en esta, no obstante, nunca debemos olvidar que la normativa ofrece unos par\u00e1metros y datos <strong><strong>m\u00ednimos<\/strong><\/strong> necesarios para proteger los riesgos planteados, por lo que siempre debemos basarnos en esta asegurando que estos m\u00ednimos se cumplen sin problemas, tanto en la teor\u00eda como en la pr\u00e1ctica. Proyectar un sistemas con el convencimiento de que \u201csobre papel todo funciona\u201d, pero con la certeza que la realidad es otra muy distinta, es un juego al que no debemos someternos, siempre habr\u00e1 empresas en el mercado que intentar\u00e1n jugar con estas cartas, pero es parte de nuestro trabajo aportar la luz necesaria a nuestro cliente para que no caiga en la trampa.<\/p>\n<p>Desafortunadamente, tambi\u00e9n es cierto que no todas las normativas y reglas t\u00e9cnicas vigentes son perfectas, aqu\u00ed es donde debemos utilizar el sentido com\u00fan para discernir c\u00f3mo debemos plantear una correcta protecci\u00f3n.<\/p>\n<p>Por poner un ejemplo que creo que todos conocemos&#8230;Llama tremendamente la atenci\u00f3n el apartado de la <em>ITC MIE APQ-001<\/em> donde para proteger el posible derrame en un cubeto, indica el n\u00famero de generadores de espuma (vertederas) que deben instalarse. Este fija el n\u00famero de generadores necesarios, bas\u00e1ndose \u00fanicamente en el di\u00e1metro del mayor de los tanques, obviando totalmente tanto el n\u00famero de ellos como el tama\u00f1o del cubeto.<\/p>\n<p><strong><em><strong>3.3. Protecci\u00f3n de incendios de derrames en cubetos. <\/strong><\/em><\/strong><\/p>\n<p><strong><em><strong>Para la protecci\u00f3n de incendios de derrames en cubetos deber\u00e1 contarse con generadores de espuma de un caudal unitario m\u00ednimo de 11,4 m3\/h (190 litros\/minuto). Para cubrir este requerimiento deber\u00e1 disponerse, al menos del n\u00famero de generadores y tiempo m\u00ednimo de aplicaci\u00f3n que se indican a continuaci\u00f3n:<\/strong><\/em><\/strong><strong><em><strong>\u00a0<\/strong><\/em><\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"260\"><strong><em><strong>Di\u00e1metro (D) en m del mayor de los tanques<\/strong><\/em><\/strong><\/td>\n<td width=\"175\"><strong><em><strong>N.\u00b0 de generadores requerido<\/strong><\/em><\/strong><\/td>\n<td width=\"189\"><strong><em><strong>Tiempo m\u00ednimo de aplicaci\u00f3n *<\/strong><\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"260\"><strong><em><strong>D &lt; 20<\/strong><\/em><\/strong><\/td>\n<td width=\"175\"><strong><em><strong>1<\/strong><\/em><\/strong><\/td>\n<td width=\"189\"><strong><em><strong>20<\/strong><\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"260\"><strong><em><strong>20 &lt; D &lt; 36<\/strong><\/em><\/strong><\/td>\n<td width=\"175\"><strong><em><strong>2<\/strong><\/em><\/strong><\/td>\n<td width=\"189\"><strong><em><strong>30<\/strong><\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"260\"><strong><em><strong>36 &gt; D<\/strong><\/em><\/strong><\/td>\n<td width=\"175\"><strong><em><strong>3<\/strong><\/em><\/strong><\/td>\n<td width=\"189\"><strong><em><strong>30<\/strong><\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"87\"><strong><em><strong>*<\/strong><\/em><\/strong><\/td>\n<td colspan=\"3\" width=\"537\"><strong><em><strong>El tiempo m\u00ednimo de aplicaci\u00f3n est\u00e1 basado en la operaci\u00f3n simult\u00e1nea del n\u00famero de generadores requerido considerando un caudal unitario de 11,4 m<sup>3<\/sup>\/h.<\/strong><\/em><\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Evidentemente esto es un gran error, y nuestro sentido com\u00fan debe alertarnos de semejantes indicaciones, seg\u00fan esto podr\u00edamos tener un cubeto de 100x50m donde ning\u00fan dep\u00f3sito sobrepasara los 20m de di\u00e1metro, \u201cprotegido\u201d con una \u00fanica vertedera de 190 l\/min de caudal unitario y un tiempo de aplicaci\u00f3n m\u00ednimo de 20 minutos, salta a la vista que esto no funciona.<\/p>\n<p>Esto es solo un ejemplo, existen otros menos evidentes pero totalmente contrarios a nuestra experiencia y sentido com\u00fan.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Muchos de los proyectos que caen en nuestras manos son susceptibles de este debate, como t\u00e9cnicos y profesionales en Sistemas de Protecci\u00f3n Contra Incendios, siempre debemos priorizar en el dise\u00f1o de nuestros sistemas su principal cometido, \u201cPROTEGER\u201d. Afortunadamente, y gracias al trabajo de grandes profesionales del sector, la normativa referente a Sistemas Contra Incendios es [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[8],"tags":[81,26,137,46,280,25,15,281,54],"soporte":[547],"class_list":["post-4025","post","type-post","status-publish","format-standard","hentry","category-proteccion-contra-incendios","tag-denuncia","tag-diseno","tag-espuma","tag-extincion-incendios","tag-itc-mie-apq-001","tag-normativa","tag-proteccion-contra-incendios-2","tag-reglamento","tag-sistema-espuma","soporte-articulo"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/posts\/4025","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/comments?post=4025"}],"version-history":[{"count":5,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/posts\/4025\/revisions"}],"predecessor-version":[{"id":4031,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/posts\/4025\/revisions\/4031"}],"wp:attachment":[{"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/media?parent=4025"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/categories?post=4025"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/tags?post=4025"},{"taxonomy":"soporte","embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/soporte?post=4025"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}