{"id":3786,"date":"2014-06-05T09:03:23","date_gmt":"2014-06-05T08:03:23","guid":{"rendered":"http:\/\/blog.prefire.es\/?p=3786"},"modified":"2021-01-15T19:15:46","modified_gmt":"2021-01-15T18:15:46","slug":"resistencia-al-fuego-de-portones-y-cierres-de-transportadores","status":"publish","type":"post","link":"https:\/\/www.prefire.es\/hub\/2014\/06\/resistencia-al-fuego-de-portones-y-cierres-de-transportadores\/","title":{"rendered":"Resistencia al fuego de portones y cierres de transportadores"},"content":{"rendered":"<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2014\/05\/DSC055481.jpg\" rel=\"nofollow noopener\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-3791 size-full\" src=\"https:\/\/blog.prefire.es\/wp-content\/uploads\/2014\/05\/DSC055481.jpg\" alt=\"DSC05548\" width=\"428\" height=\"318\" srcset=\"https:\/\/www.prefire.es\/hub\/wp-content\/uploads\/2014\/05\/DSC055481.jpg 428w, https:\/\/www.prefire.es\/hub\/wp-content\/uploads\/2014\/05\/DSC055481-303x225.jpg 303w\" sizes=\"(max-width: 428px) 100vw, 428px\" \/><\/a><\/p>\n<p>El Ministerio de Fomento, a trav\u00e9s del Blog de la UAAAP ha resuelto la consulta sobre el grado de resistencia al fuego de un hueco con un elemento compartimentador tipo port\u00f3n, y el caso espec\u00edfico de los cierres transportadores.<\/p>\n<blockquote><p><strong>Respuesta del Ministerio de fomento<\/strong><\/p>\n<p>Dada las dimensiones de los portones (puertas industriales, de garaje, etc.) muy superiores a las de las puertas de paso, se consideran tambi\u00e9n elementos m\u00f3viles de compartimentaci\u00f3n y su resistencia al fuego debe ser la misma que la exigible a los elementos fijos.<\/p>\n<p>Los cierres de transportadores suelen ser peque\u00f1os, en cuyo caso su resistencia al fuego podr\u00eda ser, como en el caso de puertas de paso, el 50% de la exigible al elemento compartimentador en el que est\u00e9n situados. Si exceden la dimensi\u00f3n de una puerta de dos hojas (m\u00e1s de 4,5 m2) se tratar\u00edan como los portones, cortinas, etc. y su resistencia al fuego deber\u00eda ser el 100%.<\/p>\n<p>Todo ello, en el marco de aplicaci\u00f3n del CTE DB SI, es decir, en aquellos establecimientos no regulados por el RSCIEI. En los regulados por el RSCIEI debe estarse a lo que establezca dicho reglamento o, en su caso, al criterio que al respecto establezca el Ministerio de Industria, Energ\u00eda y Turismo.<\/p><\/blockquote>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp; El Ministerio de Fomento, a trav\u00e9s del Blog de la UAAAP ha resuelto la consulta sobre el grado de resistencia al fuego de un hueco con un elemento compartimentador tipo port\u00f3n, y el caso espec\u00edfico de los cierres transportadores. Respuesta del Ministerio de fomento Dada las dimensiones de los portones (puertas industriales, de garaje, [&hellip;]<\/p>\n","protected":false},"author":12,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[6],"tags":[252,253,38,15,228,222,92],"soporte":[547],"class_list":["post-3786","post","type-post","status-publish","format-standard","hentry","category-cortinas-cortafuegos","tag-cierres-transportadores","tag-compartimentacion","tag-cte","tag-proteccion-contra-incendios-2","tag-resistencia-al-fuego","tag-rsciei","tag-sectorizacion","soporte-articulo"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/posts\/3786","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/comments?post=3786"}],"version-history":[{"count":5,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/posts\/3786\/revisions"}],"predecessor-version":[{"id":3793,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/posts\/3786\/revisions\/3793"}],"wp:attachment":[{"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/media?parent=3786"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/categories?post=3786"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/tags?post=3786"},{"taxonomy":"soporte","embeddable":true,"href":"https:\/\/www.prefire.es\/hub\/wp-json\/wp\/v2\/soporte?post=3786"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}